Station Post Insulators
Partial listing of the specifications for standard Newelll insulators.
Newelll-PSN offers "field proven performance" in a complete line of solid core, station post porcelain insulators. And, with over 50 years of manufacturing experience and performance testing, you can confidently specify Newelll-PSN.
All Sizes, All Strengths
Newelll offers substation post insulators for practically every application:
Non-Stacking 7.5 to 69 kV
Stacking 115 to 765 kV
|
Non-Stacking Station Post Insulators
EXAMPLE: (TR-202) - TR Number if applicable 231001 - Newelll-PSN Part Number
End Codes - Example: 231001-(7001)
Stacking Station Post Insulators
EXAMPLE: (TR-286) - TR Number if applicable 47801 - Newelll-PSN Part Number
| Partial listing of the specifications for standard Newelll insulators. |
| Newelll No. |
Height (in.) |
Leakage (in.) |
Cantilever (lbs.) |
Top B. C.(in.) |
Bottom B.C.(in.) |
| 41010 |
10 |
10.5 |
8000 |
5 |
5 |
| 41012 |
12 |
15.5 |
8000 |
5 |
5 |
| 41015 |
15 |
24 |
8000 |
5 |
5 |
| 41020 |
20 |
37 |
8000 |
5 |
5 |
| 41510 |
10 |
10.5 |
4000 |
5 |
5 |
| 41512 |
12 |
15.5 |
4000 |
5 |
5 |
| 41515 |
15 |
24 |
4000 |
5 |
5 |
| 41520 |
20 |
37 |
4000 |
5 |
5 |
| 41524 |
24 |
43 |
4000 |
5 |
5 |
| 41530 |
30 |
72 |
3000 |
5 |
5 |
| 47019 |
106 |
231 |
1000 |
5 |
5 |
| 47515 |
15 |
38 |
2000 |
3 |
3 |
| 47516 |
18 |
43 |
2000 |
3 |
3 |
| 47517 |
29 |
72 |
1500 |
3 |
3 |
| 47531 |
11 |
18 |
1750 |
3 |
3 |
| 47545 |
14 |
24 |
2000 |
3 |
3/4 " Stud mnt. |
| 47761 |
106 |
231 |
1450 |
5 |
7 |
| 47791 |
92 |
198 |
1250 |
5 |
5 |
| 47801 |
45 |
99 |
1700 |
5 |
5 |
| 47802 |
54 |
116 |
1450 |
5 |
5 |
| 47803 |
62 |
132 |
1200 |
5 |
5 |
| 47805 |
80 |
165 |
950 |
5 |
5 |
| 47807 |
92 |
198 |
800 |
5 |
5 |
| 47817 |
80 |
165 |
1450 |
5 |
5 |
| 47818 |
80 |
165 |
2750 |
5 |
7 |
| 47821 |
45 |
99 |
2600 |
5 |
5 |
| 47822 |
54 |
116 |
2200 |
5 |
5 |
| 47823 |
62 |
132 |
2000 |
5 |
5 |
| 47825 |
80 |
165 |
1450 |
5 |
5 |
| 47827 |
92 |
198 |
1250 |
5 |
5 |
| 47831 |
106 |
231 |
1000 |
5 |
5 |
| 47833 |
122 |
264 |
900 |
5 |
5 |
| 47842 |
54 |
116 |
4100 |
7 |
7 |
| 47843 |
62 |
132 |
3500 |
7 |
7 |
| 47845 |
80 |
165 |
2750 |
7 |
7 |
| 47847 |
92 |
198 |
2300 |
7 |
7 |
| 47848 |
122 |
264 |
1750 |
5 |
7 |
| 47851 |
106 |
231 |
2050 |
7 |
7 |
| 47853 |
122 |
264 |
1750 |
7 |
7 |
| 47854 |
152 |
360 |
1400 |
5 |
7 |
| 47855 |
182 |
432 |
1200 |
5 |
7 |
| 47862 |
106 |
231 |
2050 |
5 |
7 |
| 47950 |
92 |
198 |
2300 |
5 |
7 |
| 48123 |
92 |
198 |
2000 |
5 |
7 |
| 48188 |
155 |
360 |
2500 |
7 |
14 |
| 231001 |
7.5 |
10.5 |
2000 |
3 |
3 |
| 231002 |
10 |
15.5 |
2000 |
3 |
3 |
| 231003 |
14 |
24 |
2000 |
3 |
3 |
| 231004 |
18 |
37 |
2000 |
3 |
3 |
| 231005 |
22 |
43 |
2000 |
3 |
3 |
| 231006 |
30 |
72 |
1500 |
3 |
3 |
Sylgard® COATED POSTS NOW AVAILABLE
Newelll PSN offers porcelain insulators with high-leakage OR Sylgard coating for high contamination areas.
|
Newelll-PSN
High Leak Insulators are available in a full line of standard voltage models; and, WE WILL QUOTE SPECIAL CUSTOMER DESIGNS.
|
THE INSTALLATION BENEFITS OF SYLGARD COATED INSULATORS ARE:
- No washing
- No resistive power loss... means lower overall cost
- No loss of stability with over-voltage
- Ideal for installation areas prone to salt spray or industrial contaminants
|